Macurco OX-6 Oxygen Detector, Controller and Transducer, 12-24 VAC or 12-32 VDC

  • JMAC SKU: MACURCO-OX-6
$481.90
+ Free Shipping
In Stock
  • Expedited Shipping Available Expedited Shipping Available
  • Need it Tomorrow?
    Need it Tomorrow?
    Select the NEED IT FAST shipping option at checkout and a member of our team will contact you promptly with any available Expedited Shipping options once we receive your order.
JMAC_ID:
200470833
df_manual_boost:
1.75
The Macurco OX-6 is a low voltage, dual relay Oxygen (O2) detector, controller and transducer. The OX-6 has selectable 4-20 mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of Oxygen and provide feedback and automatic exhaust fan control to help maintain appropriate Oxygen concentrations in commercial applications. The OX-6 is a low level meter capable of detecting from 0-25% by volume of Oxygen.

The OX-6 is also available in White.

UPC: 783748834907
Also known as: OX6

Technical Specifications:
  • Power: 3 W (max) from 12 to 24 VAC or 12 to 32 VDC
  • Current @ 24 VDC: 75 mA in alarm, 50 mA fan relay on and 23 mA stand by
  • Shipping Weight: 1 pound (0.45 kg)
  • Size: 4 1/2 x 4 x 2 1/8 in. (11.4 X 10.2 X 5.4 cm)
  • Color: Dark gray
  • Connections: plugs/terminals
  • Mounting box: (not included) 4x4 electric
  • Fan relay: 5 A, 240 VAC, pilot duty, SPDT, latching or non-latching
  • Fan relay actuation: selectable at OFF, 18, 18.1… , 20.2 (default), 20.3, 20.4 & 20.5% v/v and high 23.5 % v/v (preset)
  • Fan Delay Settings of 0, 1, 3 (default), 5 and 10 minutes
  • Fan Minimum Runtime settings are OFF (default), 3, 5, 10 or 15 minutes
  • Current Loop, 4-20 mA for 0-25% v/v O2
  • Alarm relay: 0.5A 120 V, 60 VA
  • Alarm relay actuation: selectable N.O. default or N.C.
  • Alarm relay settings: OFF, 18.5, 19, 19.5 (default), 20, 20.5 and high 23.5 % v/v (preset)
  • Operating Environment: 0°F to 125° F (-18°C to 52°C),10 to 90% RH non-condensing


For more information about the Macurco OX-6, please contact us.
  • Dark gray housing
  • Fan relay actuation: selectable at 18, 18.1… , 20.2 (default), 20.3, 20.4 & 20.5% v/v and high 23.5 % v/v (preset)
  • Output: Fan relay, Alarm relay and 4-20mA current loop
  • Controls: Digital display (0-25% v/v), buzzer, fan delay, fan minimum runtime
  • Mounts on a standard 4” x 4” electrical box
  • 5 A SPDT fan relay controls valves, louvers or exhaust fans
  • 0.5 A N.O. or N.C alarm relay connects to warning devices or control panels
  • 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel
  • Factory calibrated
  • Supervised system design: detector problem will cause the fan & alarm relay to activate
  • Optional calibration test kit allows the OX-6 to be field calibrated and tested
  • ETL Listed to UL 61010-1, CAN/CSA C22.2 No 61010-1

1 Review

  • 5
    MACURCO-OX-6

    Posted by 171408 on Jun 8th 2021