Honeywell Access PRO32OUT 16 Relay Output Module

  • JMAC SKU: HONEYWELL-ACCESS-PRO32OUT
$695.87
+ Free Shipping
In Stock
The PRO32OUT interfaces with the intelligent control module (PRO32IC) providing up to 12 or 16, Form C, 12 VDC, 2A relay output controls depending if the board is rack or tile-mounted and power fail and panel tamper when tile mounted. Relays may be used for elevator control, status annunciation and for general facility control, such as door monitoring.

UPC: 886618196782
Also known as: NC-PRO32OUT, HCS-PRO32OUT

Technical Specifications:
  • Alarm Inputs: 2 dedicated alarm inputs for tamper detection and power loss (tile-mounted only)
  • Output Relays: 12 general purpose output relays, form C, 2 A 30 VDC, (16 are available when using PRO22ENC3 tile-mounted enclosure)
  • Outputs: All 16-relay outputs in the tile-mount configuration, (12" rack-mount) are available for general purpose I/O
  • Dry Circuit Logic: The 2 A relays are rated to handle dry circuit logic
  • Pulse Time: 1-32,400 seconds
  • Configurable: Configurable as standard (energize to activate) N/A or fail-safe (de-energize to activate)
  • Measurements: RS485 port, 4,000 ft (1,250m) total bus length per port
  • Speed: 38.4 Kbps


For more information about the Honeywell Access PRO32OUT, please contact us.
  • Modular design fits a wide variety of applications
  • Up to 9 modules, power-supply and battery can be accommodated by the PRO22ENC1, PRO22ENC2 and PRO22ENC5 (no battery) enclosures
  • User programmable relay outputs allow for specific control needs
  • User programmable alarm inputs offer flexible system configuration and control
  • RS485 communication to all modules
  • Analog to digital converter technology provides digital filtering and input conditioning
  • Dedicated cabinet tamper and power monitor inputs
  • Supports the choice of normally open, normally closed, supervised, and nonsupervised circuits
  • Supports a wide range of reader technologies including Wiegand, magnetic stripe, proximity, and keypad
  • System off-line modes customizable per reader include facility code access, locked (no access), and unlocked (full access)
  • Supports multiple reader and card formats for maximum flexibility and security options
  • Operating modes include locked, unlocked, facility code, card only, card and PIN, card or PIN and PIN only
  • Communication to the host is via either 10/100 Ethernet or RS-232 (both are standard)
  • Alarm circuit type - normally open, normally closed, non-supervised, supervised (with correct EOL). Meets requirements for UL294 and CUL
  • Any combination of 16 I/0 or readers modules may be connected to the PRO32IC RS485 ports. 4,000 ft (1,250 m) total bus length per port
  • Supports over 50,000 cards and 50,000 transactions


1 Review

  • 5
    HONEYWELL-ACCESS-PRO32OUT

    Posted by 80055 on Feb 2nd 2015