The PRO32OUT interfaces with the intelligent control module (PRO32IC) providing up to 12 or 16, Form C, 12 VDC, 2A relay output controls depending if the board is rack or tile-mounted and power fail and panel tamper when tile mounted. Relays may be used for elevator control, status annunciation and for general facility control, such as door monitoring.
UPC: 886618196782
Also known as: NC-PRO32OUT, HCS-PRO32OUT
Technical Specifications:
- Alarm Inputs: 2 dedicated alarm inputs for tamper detection and power loss (tile-mounted only)
- Output Relays: 12 general purpose output relays, form C, 2 A 30 VDC, (16 are available when using PRO22ENC3 tile-mounted enclosure)
- Outputs: All 16-relay outputs in the tile-mount configuration, (12" rack-mount) are available for general purpose I/O
- Dry Circuit Logic: The 2 A relays are rated to handle dry circuit logic
- Pulse Time: 1-32,400 seconds
- Configurable: Configurable as standard (energize to activate) N/A or fail-safe (de-energize to activate)
- Measurements: RS485 port, 4,000 ft (1,250m) total bus length per port
- Speed: 38.4 Kbps
|
For more information about the Honeywell Access PRO32OUT, please